SUGGESTED WIRING
Input - High Range MonitoredActive High - 24VDC Locally Sourced
Notes: Vocia software congured as High Range Monitored  - Active State High.
Circuit shown in Low State
Input - High Range MonitoredActive High - 24VDC Externally Sourced
Notes: Vocia software congured as High Range Monitored  - Active State High.
Circuit shown in Low State
Input - High Range UnmonitoredActive High - 24VDC Locally Sourced
Notes: Vocia software congured as High Range  - Active State High.
Circuit shown in Low State
Input - High Range UnmonitoredActive High - 24VDC Externally Sourced
Notes: Vocia software congured as High Range  - Active State High.
Circuit shown in Low State